| Keterangan: | Technical Data
O² -measurement
• Range : 0...21.0 Vol.-%
• Accuracy : 0.3 Vol.-% absolut
CO-measurement-solid fuel ( optional)
• Range : 0...4, 000 ppm
• Accuracy : ± 20 ppm: 0...400 ppm, ± 5% o.r.
NO-measurement ( optional)
• Range : 0...2, 000 ppm, continually resilient up to 1, 000 ppm
• Accuracy : 5 ppm: 0...100 ppm 5 % o.r.
NO2-measurement ( optional)
• Range : 0...500 ppm
• Accuracy : ± 5 ppm: 0...100 ppm, ± 5% o.r.
SO2-measurement ( optional)
• Range : 0...4, 000 ppm
• Accuracy : ± 10 ppm: 0...200 ppm, ± 5% o.r.
Ambient air temperature-TA
• Range : -20.0...99.9 ° C
• Accuracy : 1 ° C: 0...50 ° C
Flue Gas temperature measurement-TS
• Range : 0...800 ° C
• Accuracy : according to EN 50379
Draft and Differential Pressure-DP
• Range : 0...± 4, 000 Pa
• Accuracy : 3 Pa: 0...100 Pa, 3 % v.M.: 100...4, 000 Pa
CO2-Calculation
• Range : 0...CO2max
• Resolution : 0, 10%
Stack losses-QA
in reference to selected fuel
• Resolution : 0, 10%
Efficiency - ?
• Range : 0...100.0 % condensation is automatically detected
• Resolution : 0, 10%
Automatic CO purge pump dew point calculation:
in reference to the selected fuel,
• Resolution : 0.1 ° C
Condensate
• readings in kg/ m3 ( gas) or kg/ l ( oil)
Date / time
realtime clock with backup battery
• Storage temperature : -20...50 ° C
• Work temperature : 5...40 ° C
to meet specifications
Current supply
4 x AA rechargeable batteries or mains supply
• Weight : ca. 1, 300 g
• Size : 213 x 172 x 73 mm
Standard Unit A-500 :
• Sensor : O2, CO, NO, SO2
• Air temp. probe with 1.6 m cable
• Wö hler RP 72 soot pump set
• 25 pcs. Wadding
• 5 pcs. Coarse filter
• 3 pcs. Water stop filter
• Sluminium framed case
• Thermal fast printer |